Sargent & Greenleaf 6129 Comptronic
Summary
- rating: A-Series (Models 6128/6129) is marked: RoHS2 Compliant; A2P Class B/E; VdS Class 2; ECB-S R01 Lock Guide…
- order code: 6128-240 / 6129-240 lock kit (lock, keypad, keypad extension, serial number plate): non-tamper keypad yes…
- mounting: lock bolt not fastened straight to the safe's boltwork: minimum gap 0.150 inch (3.8 mm), measured from the…
- Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
- Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
- Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
- UL Certificate of Compliance 20140106-BP8812, Sargent & Greenleaf high-security electronic locks Type 1, Models 6128 and 6129, 2014-01-06 · UL LLC · 2014
Specifications
rating
A-Series (Models 6128/6129) is marked: RoHS2 Compliant; A2P Class B/E; VdS Class 2; ECB-S R01 Lock Guide Class B; EN 1300 Class B; UL Listed Type 1. Certifications not shown are not marked; that is not a claim the lock lacks them.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
UL Listed Type 1; A2P B/E; VdS Class 2; CEN B; DNV 3492 is not marked.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
6128 and 6129 A-series ATM Locks page (rev 6/23/2014). As printed: UL Listed Type 1, VdS Class 2, CEN B, A2P B/E, RoHS compliant (DNV not listed).
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
UL Listed high-security electronic locks, Type 1: models 6128 and 6129 with optional 6102 battery box, evaluated under Subject 2058, High-Security Electronic Locks. UL certificate 20140106-BP8812 (report BP8812-20001109, issued 2014-01-06 to Sargent & Greenleaf Inc, 1 Security Dr, Nicholasville KY 40356). Only products bearing the UL Listing Mark are covered by the listing and Follow-Up Service; more detail is in the UL Online Certifications Directory (www.ul.com/database).
UL Certificate of Compliance 20140106-BP8812, Sargent & Greenleaf high-security electronic locks Type 1, Models 6128 and 6129, 2014-01-06 · UL LLC · 2014
order code
6128-240 / 6129-240 lock kit (lock, keypad, keypad extension, serial number plate): non-tamper keypad yes, keypad extension yes, BPI yes, reset code no.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
Accessories: 6103-130, 6103-131, 6103-102, 6104-006, 6102-025 (same as for the 6126/6127).
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
6128-500: A-seal box with 9-volt battery. 6102-302: Field Service App (FSA) software with iButton reader, USB adapter and MICRO-USB connector for Android; 6102-303: the same with a MINI-USB adapter.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
mounting
lock bolt not fastened straight to the safe's boltwork: minimum gap 0.150 inch (3.8 mm), measured from the bolt end of the lock case to the closest point of the blocking bar or cam plate
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
Install clearance min 0.150 in (3.8 mm) lock-case-to-blocking-bar; wire channel min 5/16 in (8 mm); bolt throw >0.46 in (11.7 mm) needs 0.075 in (2 mm) spacer; design load 2.25 lb (10 N), max intermittent 5.5 lb (25 N).
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
Keep the blocking bar or cam plate from rubbing or binding against the lock bolt end when the bolt is retracted. Rated to move a 2.25 lb (10 N) load; maximum intermittent load 5.5 lb (25 N).
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
attached device must move in line with the lock bolt; needs a micro switch (not included) to trigger bolt extension; mounting surface smooth and flat, mounting screw holes threaded 1/4-20 (or M6)
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
Wire channel (spindle hole) minimum diameter 5/16 inch (8 mm); remove sharp edges inside and outside.
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
If the bolt throw needed is over 0.46 inch (11.7 mm), take out the bolt travel adjustment screw and put a 0.075 inch (2 mm) spacer (not included) on the end of the lock bolt.
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
catalog date
1998-09
drawing dimensions
Dimensions-6125, 6127, 6129 Series Case, as printed: case 3.320 (84,3 mm) x 2.400 (61,0 mm); holes 2.624 (66,6 mm) x 1.624 (41,2 mm); bolt 1.000 (25,4 mm); locked.461 (11,71 mm), unlocked.125 (3,18 mm); depth 1.165 (30 mm).
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
bolt.312 (7,9 mm),.281 (7,1 mm); two M4-.7 holes.59 (15 mm) apart in the bolt; Accommodates direct boltwork attachment, push/pull 2.24 lbs (10 N), maximum load 5.6 lbs (25 N).
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
Adjustable throw: standard locked 0.461, unlocked 0 (flush), throw 0.461 (11,71 mm); with the bolt travel screw removed unlocked -0.08 (-2 mm, recessed), throw 0.54 (13,71 mm); for more than.46 in travel remove the screw and add a.075 in (2 mm) spacer.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
User-supplied boltwork switch: min 30 VDC, min 50 mA, silver contacts, snap acting, lock bolt extends on contact closure, lever or roller actuator, min 50,000 cycles,.110 x.020 in (2.8 x.5 mm) quick connect tabs.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
Bolt (Q42, resolved): standard unlocked 0 (flush with case), locked.461 in, throw.461 in; with the travel screw removed unlocked -.08 in (recessed), throw.54 in, as in S&G 630-610 (6127/6129 installation instructions); the drawing's unlocked.125 matches neither and is not recorded.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
feature function
Chart for A-Series (Models 6128/6129): single control: bank mode; dual control: bank mode; manager/employee: bank mode.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Chart marks the Manual Secure function, printed as (0, 0, #) (Model 6129-231 only). No other opening or closing steps are printed in the catalog.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Total number of codes (programmer, manager and user codes): 18. The chart refers to the operating instructions for the breakdown of codes.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Time delay 1-99 minutes; no time delay override code marked.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Penalty lockout is marked as a feature. The length of the lockout period is not printed.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Audit trail 400 events (Order 3103-095); audit download by Dallas iButton; email capability for audit events: not marked.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Duress/silent alarm capability: Order 6102-090. Duress code: last code digit entered one number higher (6102-090 entry); an optional module is needed to interface with an alarm company (feature notes on the product page).
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Electronic safeguards printed for A-Series (Models 6128/6129): penalty lockout, time delay, duress option. No other attack-resistance claim is printed for this entry.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Bank mode: opens without a key, using two forms of authentication.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Steps not printed. Printed code control: managers specify a 4-, 8-, 12- or 24-hour window during which a code is live; opening codes are generated in the Lock Management Software (LMS).
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
One-time-code app: supervisors set time windows for network access; codes live only during the window; codes are generated from a mobile device (Android app; web application for all mobile devices). Key-press steps are not printed.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
The catalog does not use the word autodialer; it marks penalty lockout for this lock and its glossary defines penalty timeout as stopping operation for a preset period to delay opening by trying sequential or random codes.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Not printed in this catalog (number of wrong entries before lockout).
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Not printed in this catalog (battery type).
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Not printed in this catalog (steps to change the battery).
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Not printed in this catalog (external battery pack).
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
6128/6129 are the A series, designed for the ATM market, with one-time-use opening codes generated by special software; the 6129 differs from the 6128 with a push/pull motor design.
SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009
The two-battery 61KP keypad (rectangular buttons) works with every S&G electronic lock except Direct Drives, but usually appears only on the 6124/6125, 6126/6127 and 6128/6129. Z02 and Z03 Direct Drive solenoid locks pair only with Direct Drive keypads (yellow or blue tab).
SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009
The 6126 through 6129 have a four-pin and a six-pin cable exiting the case from two different edges; the six-pin one connects the Dallas-style key reader. Direct Drive and Z03 RotaryBolt locks use one round four-pin keypad cable instead of a ribbon.
SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009
Model 6128 ATM banking lock: operation may be Bank Mode alone, Service Mode alone, or both together. In Bank Mode Only, bank users locally control PIN positions, codes, and keypad programming; Service Mode Only needs the Lock Management System for Touch Memory Keys and one-time Operation codes.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Factory default PIN positions and codes as printed: Programmer Code, PIN 00, is 123456 (it cannot open the lock; it configures parameters and downloads the audit); Officer Code, PIN 02, is 020202; User Code, PIN 10, is 101010.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
PIN structure (PDF §2.2): each user has a 2-digit PIN position (role) and a 6-digit PIN Code; together they form the 8-digit User Code ending with #; Users can change their own PIN Code but not their PIN position.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Bank User Group access (PDF Table B): Officers (02–03) open (except Manager/Employee mode), enable/disable users in Manager/Employee mode, add/delete users (second valid code required), start time delay, send duress, act as second Dual Control code, change own PIN.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Penalty time / Bank Mode (PDF §2.6): five incorrect codes in a row put the lock into a 10-minute penalty lockout; it cannot be opened; further input during penalty does not extend the lockout; after 10 minutes, a valid code is accepted.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Batteries (PDF §2.9–2.10): low battery — correct User Code opens then five double-beeps; too-low — 20 beeps and lock will not open; Uses two 9-volt alkaline batteries behind the keypad (Duracell alkaline recommended); Codes and program settings are retained while batteries are changed.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Bank Mode programming commands: 22* changes the PIN Code; 28* pulls the audit log (an option under Service Mode); 32* selects the access mode; 38* turns duress on or off (a duress module is required); 43* identifies the lock type; 54* initializes the lock (Service Mode); 57* resets the microprocessor.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Audit trail (PDF §3.2 Command 28): stores as many as 400 time-and-date events (add/delete code, change code, open/close, programming such as set date); Download to Touch Memory key then upload via Comptronic Lock Management System software.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Access modes selected with Command 32*: Multiple User — any valid code except the Programmer Code opens the lock. Manager/Employee — Officers or Administrators can turn User Codes on or off; Officer/Admin PINs will not unlock it under that setting.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Duress: with the module installed and the feature turned on (Command 38*), enter a User Code whose final digit is one above or one below the usual PIN, then # (if the usual last digit is 0, use 1 or 9). The lock still operates normally while sending duress.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Time delay, Bank Mode only (§3.10): adjustable from 0-99 minutes (factory default none / 0). The opening window defaults to 2 minutes and can be set from 1-10 minutes.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Service mode: needs a Dallas iButton touch key, a four-digit PIN and an eight-digit one-time code (OTC) generated for a set time window in the Lock Management Software.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Bank + Service mode lets personnel of either type reach the ATM. Operating key-press steps are not given.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
The Low-Profile keypad (black tab) does not work with Direct Drive locks or the 6126 through 6129 series.
SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009
the lockout length and wrong-entry count are not printed.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Bank User PIN codes disabled; Bank and Service Mode — bank users keep local PIN control and limited keypad programming; LMS controls Bank optional features and Service codes.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Bank User Group: up to 16 PIN positions — Officers 02–03, Administrators 04–07, Users 10–19; Opening uses 2-digit PIN position + 6-digit PIN Code (8 digits) then #; Default access mode is Multiple User (any valid code other than Programmer).
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Guide recommends changing PIN Codes immediately after assignment.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Programmer (00) configures the lock and downloads audit; cannot open; used with LMS to initiate Service Mode (command 54) and with other codes for commands 28, 32, 38, 73, 74, and 78.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Administrators (04–07) open (except Manager/Employee), enable/disable users, delete users (second code), start time delay, send duress, Dual Control second code, change own PIN (add-user not listed for Administrators in Table B).
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
entering a code during lockout yields two long tones (brap); clear entry errors with * * or wait 10 seconds between entries (§2.5).
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Remove keypad housing from the bottom edge (S&G logo side), replace both batteries, support battery holders. iButton Touch Key transfers audit trail and authorizes Service Mode users (§2.11); requires Lock Management System or Audit Manager software.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
73* set date (Bank Mode only); 74* add/delete User PIN Codes and set time delay; 77* PIN-position confirmation; 78* set time (Bank Mode only).
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Download uses Programmer PIN 00 plus cipher code from LMS; yellow LED on during ~20 s transfer; three beeps on success.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Dual Control — two independent valid User or Management codes required to open.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
all User Codes can send duress, including during programming; Factory default: duress disabled (§1.3).
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
User enters code to start delay; LED flashes and single beep every 10 s during delay; 10 rapid beeps when delay expires; during opening window beep+LED twice every 6 s; if not opened in window, lock resets.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Changes to an already-set delay/window only during the opening window; do not set delay until other programming is finished; Command 74* function 00 = delay minutes; function 01 = opening window.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
install test
Pre-install check: press 10101010# and watch the bolt retract, then extend again 15 seconds later; Duracell alkaline batteries are the type S&G recommends; the installer should wear a grounded ESD wrist strap; modifying the lock is not recommended and voids the manufacturer’s warranty.
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
lock options
A-Series kit order numbers: 6128-247 kit, auto relocking square bolt, 2-battery keypad, satin chrome; 6129-240 kit, push/pull square bolt, 2-battery keypad, satin chrome.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
specifications
A-Series (Models 6128/6129): bolt position indicator (BPI): yes; management reset code: not marked; marked lock body: Auto Relocking Square Bolt (motor lock); marked lock body: Push/Pull Square Bolt (motor lock).
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
A-Series (Models 6128 and 6129): tested and proven ATM security; streamlined, economical format; easy access and auditing It shares the three modes of operation and the 4/8/12/24-hour code window, time delay 1-99 minutes, penalty lockout and optional duress module described on the page.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Auto Relocking Square Bolt: motor retracts the bolt to open and spring extension closes it; withstands 225 pounds of bolt-end pressure; does not require direct attachment of the bolt to the safe boltwork. (Chart marks this lock body type.)
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Push Pull Square Bolt: motor retracts the bolt to open and motor extends it to close; designed for direct boltwork attachment; bolt has drilled and tapped holes; maximum load 5.6 pounds; Push/pull strength 2.4 pounds force.
Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021
Electronic Lock Features Chart (rev 6/23/2014), column 6129 A-SERIES: dual user, manager/employee modes; programmer code; 2 officer codes; 4 administrator codes; 10 user codes; total 16; duress module 6102-090; time delay 1-99 min; penalty lockout; BPI order 6129-230; motor drive.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
A-series ATM lock: up to sixteen users in Bank Mode (1 programmer, 2 officer, 4 administrator, 10 user codes).
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
Factory defaults as printed (§1.3): Bank Mode is on and is not time-restricted; Multi-User operation is on; Time Delay is zero (0) minutes; Duress is off; audit download is on; Set Date / Time is on.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
Bolt position indicator (BPI): dry contact switch 200 VDC, 0.5 A max; Black=common; green completes to black when bolt retracted; red completes to black when bolt extended.
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
Dual control and manager/employee modes are chosen with a special keypad command; snap-in touch key reader; penalty time; time delay 1-99 minutes.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
400-event audit trail (software kit 6103-120) with the time kept in the lock; duress via module 6102-090 or alarm interface module 6102-025; every model has a bolt position indicator.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
The 6129 attaches directly to boltwork, with push/pull force 2.24 lbs (10 N) and maximum load 5.6 lbs (25 N).
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
The product chart lists Multiple User Mode for the A-series, but this model description lists only dual control and manager/employee.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
Footnote *: total counts only codes that open the lock (not time delay override or programming/audit codes). **: with time delay override disabled an extra user code is available (max 9 user codes; 8 if override enabled), 3 available when duress is enabled.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
FLAG: chart marks Multiple User Mode; product page lists only dual control and manager/employee; March 2021 catalog dropped the Multiple User Mode row (neither confirms nor refutes); no value is given for Multiple User Mode.
Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014
Blue wire pair must connect to a boltwork position switch (not included) that closes when boltwork is positioned so the lock bolt can extend; lock bolt will NOT extend if the blue wire loop is open.
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
notes
6124-6129 and Z03 respond to the * 8 # test with a long steady error tone; then 4 3 * separates the models (see the 6120/6123 identification entry for the beep table).
SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009
Not printed in the article: lockout after wrong entries, anti-manipulation, anti-autodialer, battery chemistry or external battery pack. (Drill points and opening methods are mentioned as differing by model but are not described.)
SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009
Document 630-600 cover: Aseries Access Management System, Programming and Operations Guide, Models 6128 and 6129. Indoor use only; clean keypad with soft dry cloth (no solvents); never lubricate lock or keypad; support keypad when removed so it does not hang by the cable; each accepted keystroke beeps and lights the LED; all codes end with #.
Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009
If the safe has a relock device; attach the plate that normally holds it in check; fasten to the lock body (usually at the lower left cover screw) Cover screws must engage the lock body by at least four threads.
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
after install: insert one 9-volt battery in each of the keypad’s two battery holders (Duracell recommended); Keypad cable connector is keyed; for 6127 Audit Lock refer to its programming instructions for default code(s).
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
for 6129 A-Series with iButton: operational trial uses PIN+# (example 1234#); lock beeps three times and retracts; bolt extends approximately three seconds after extend on third trial.
Sargent and Greenleaf Model 6127 Audit Lock and 6129 A-SERIES Installation Instructions, Document 630-610, revised 3/19/2010 · Sargent and Greenleaf · 2010
Restricted
Drill points
Member content. 1 fact on file. The values are not shown here.
Bypass
Member content. 1 fact on file. The values are not shown here.