rating

A-Series (Models 6128/6129) is marked: RoHS2 Compliant; A2P Class B/E; VdS Class 2; ECB-S R01 Lock Guide Class B; EN 1300 Class B; UL Listed Type 1. Certifications not shown are not marked; that is not a claim the lock lacks them.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

UL Listed Type 1; A2P B/E; VdS Class 2; CEN B; DNV 3492 is not marked.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

6128 and 6129 A-series ATM Locks page (rev 6/23/2014). As printed: UL Listed Type 1, VdS Class 2, CEN B, A2P B/E, RoHS compliant (DNV not listed).

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

UL Listed high-security electronic locks, Type 1: models 6128 and 6129 with optional 6102 battery box, evaluated under Subject 2058, High-Security Electronic Locks. UL certificate 20140106-BP8812 (report BP8812-20001109, issued 2014-01-06 to Sargent & Greenleaf Inc, 1 Security Dr, Nicholasville KY 40356). Only products bearing the UL Listing Mark are covered by the listing and Follow-Up Service; more detail is in the UL Online Certifications Directory (www.ul.com/database).

UL Certificate of Compliance 20140106-BP8812, Sargent & Greenleaf high-security electronic locks Type 1, Models 6128 and 6129, 2014-01-06 · UL LLC · 2014

order code

6128-240 / 6129-240 lock kit (lock, keypad, keypad extension, serial number plate): non-tamper keypad yes, keypad extension yes, BPI yes, reset code no.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

Accessories: 6103-130, 6103-131, 6103-102, 6104-006, 6102-025 (same as for the 6126/6127).

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

6128-500: A-seal box with 9-volt battery. 6102-302: Field Service App (FSA) software with iButton reader, USB adapter and MICRO-USB connector for Android; 6102-303: the same with a MINI-USB adapter.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

mounting

The mounting surface must be flat and smooth with 1/4-20 (M6) screw holes, and the wire channel (spindle hole) must be at least 5/16 in (8 mm) across, with sharp edges removed on both sides of the door.

Sargent and Greenleaf Model 6128 A-Series Installation Instructions, 630-821, July 2010 · Sargent & Greenleaf, Inc., Nicholasville, Kentucky · 2010

Keep at least 0.150 in (3.8 mm) between the bolt end of the lock case and the nearest blocking bar or cam plate. That part must not press the bolt in farther than it retracts on its own, or operation can become inconsistent or fail.

Sargent and Greenleaf Model 6128 A-Series Installation Instructions, 630-821, July 2010 · Sargent & Greenleaf, Inc., Nicholasville, Kentucky · 2010

The keypad extension base can be fitted in four orientations, and the keypad base is held by 8-32 (M4) screws that also retain the extension. Wear an ESD wrist strap while handling the lock.

Sargent and Greenleaf Model 6128 A-Series Installation Instructions, 630-821, July 2010 · Sargent & Greenleaf, Inc., Nicholasville, Kentucky · 2010

catalog date

1998-09

drawing dimensions

6124, 6126, 6128 and 6300 series case: 3.320 (84,3 mm) x 2.400 (61,0 mm); holes 2.624 (66,6 mm) x 1.624 (41,2 mm); depth 1.165 (30 mm).

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

Bolt 1.000 (25,4 mm); bolt extension.461 (11,71 mm) locked,.125 (3,18 mm) unlocked; since 2002 the bolt retracts flush or nearly flush with the case end; bolt.312 (7,9 mm),.281 (7,1 mm).

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

The same.150 in (3.8 mm) boltwork caution applies. Direct boltwork attachment is not recommended.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

feature function

Chart for A-Series (Models 6128/6129): single control: bank mode; dual control: bank mode; manager/employee: bank mode.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Chart marks the Manual Secure function, printed as (0, 0, #) (Model 6129-231 only). No other opening or closing steps are printed in the catalog.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Total number of codes (programmer, manager and user codes): 18. The chart refers to the operating instructions for the breakdown of codes.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Time delay 1-99 minutes; no time delay override code marked.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Penalty lockout is marked as a feature. The length of the lockout period is not printed.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Audit trail 400 events (Order 3103-095); audit download by Dallas iButton; email capability for audit events: not marked.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Duress/silent alarm capability: Order 6102-090. Duress code: last code digit entered one number higher (6102-090 entry); an optional module is needed to interface with an alarm company (feature notes on the product page).

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Electronic safeguards printed for A-Series (Models 6128/6129): penalty lockout, time delay, duress option. No other attack-resistance claim is printed for this entry.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Bank mode: opens without a key, using two forms of authentication.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Steps not printed. Printed code control: managers specify a 4-, 8-, 12- or 24-hour window during which a code is live; opening codes are generated in the Lock Management Software (LMS).

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

One-time-code app: supervisors set time windows for network access; codes live only during the window; codes are generated from a mobile device (Android app; web application for all mobile devices). Key-press steps are not printed.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

The catalog does not use the word autodialer; it marks penalty lockout for this lock and its glossary defines penalty timeout as stopping operation for a preset period to delay opening by trying sequential or random codes.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Not printed in this catalog (number of wrong entries before lockout).

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Not printed in this catalog (battery type).

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Not printed in this catalog (steps to change the battery).

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Not printed in this catalog (external battery pack).

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

6128/6129 are the A series, designed for the ATM market, with one-time-use opening codes generated by special software; the 6129 differs from the 6128 with a push/pull motor design.

SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009

The two-battery 61KP keypad (rectangular buttons) works with every S&G electronic lock except Direct Drives, but usually appears only on the 6124/6125, 6126/6127 and 6128/6129. Z02 and Z03 Direct Drive solenoid locks pair only with Direct Drive keypads (yellow or blue tab).

SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009

The 6126 through 6129 have a four-pin and a six-pin cable exiting the case from two different edges; the six-pin one connects the Dallas-style key reader. Direct Drive and Z03 RotaryBolt locks use one round four-pin keypad cable instead of a ribbon.

SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009

Model 6128 ATM banking lock: operation may be Bank Mode alone, Service Mode alone, or both together. In Bank Mode Only, bank users locally control PIN positions, codes, and keypad programming; Service Mode Only needs the Lock Management System for Touch Memory Keys and one-time Operation codes.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Factory default PIN positions and codes as printed: Programmer Code, PIN 00, is 123456 (it cannot open the lock; it configures parameters and downloads the audit); Officer Code, PIN 02, is 020202; User Code, PIN 10, is 101010.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

PIN structure (PDF §2.2): each user has a 2-digit PIN position (role) and a 6-digit PIN Code; together they form the 8-digit User Code ending with #; Users can change their own PIN Code but not their PIN position.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Bank User Group access (PDF Table B): Officers (02–03) open (except Manager/Employee mode), enable/disable users in Manager/Employee mode, add/delete users (second valid code required), start time delay, send duress, act as second Dual Control code, change own PIN.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Penalty time / Bank Mode (PDF §2.6): five incorrect codes in a row put the lock into a 10-minute penalty lockout; it cannot be opened; further input during penalty does not extend the lockout; after 10 minutes, a valid code is accepted.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Batteries (PDF §2.9–2.10): low battery — correct User Code opens then five double-beeps; too-low — 20 beeps and lock will not open; Uses two 9-volt alkaline batteries behind the keypad (Duracell alkaline recommended); Codes and program settings are retained while batteries are changed.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Bank Mode programming commands: 22* changes the PIN Code; 28* pulls the audit log (an option under Service Mode); 32* selects the access mode; 38* turns duress on or off (a duress module is required); 43* identifies the lock type; 54* initializes the lock (Service Mode); 57* resets the microprocessor.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Audit trail (PDF §3.2 Command 28): stores as many as 400 time-and-date events (add/delete code, change code, open/close, programming such as set date); Download to Touch Memory key then upload via Comptronic Lock Management System software.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Access modes selected with Command 32*: Multiple User — any valid code except the Programmer Code opens the lock. Manager/Employee — Officers or Administrators can turn User Codes on or off; Officer/Admin PINs will not unlock it under that setting.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Duress: with the module installed and the feature turned on (Command 38*), enter a User Code whose final digit is one above or one below the usual PIN, then # (if the usual last digit is 0, use 1 or 9). The lock still operates normally while sending duress.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Time delay, Bank Mode only (§3.10): adjustable from 0-99 minutes (factory default none / 0). The opening window defaults to 2 minutes and can be set from 1-10 minutes.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Service mode: needs a Dallas iButton touch key, a four-digit PIN and an eight-digit one-time code (OTC) generated for a set time window in the Lock Management Software.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Bank + Service mode lets personnel of either type reach the ATM. Operating key-press steps are not given.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

The Low-Profile keypad (black tab) does not work with Direct Drive locks or the 6126 through 6129 series.

SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009

the lockout length and wrong-entry count are not printed.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Bank User PIN codes disabled; Bank and Service Mode — bank users keep local PIN control and limited keypad programming; LMS controls Bank optional features and Service codes.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Bank User Group: up to 16 PIN positions — Officers 02–03, Administrators 04–07, Users 10–19; Opening uses 2-digit PIN position + 6-digit PIN Code (8 digits) then #; Default access mode is Multiple User (any valid code other than Programmer).

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Guide recommends changing PIN Codes immediately after assignment.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Programmer (00) configures the lock and downloads audit; cannot open; used with LMS to initiate Service Mode (command 54) and with other codes for commands 28, 32, 38, 73, 74, and 78.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Administrators (04–07) open (except Manager/Employee), enable/disable users, delete users (second code), start time delay, send duress, Dual Control second code, change own PIN (add-user not listed for Administrators in Table B).

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

entering a code during lockout yields two long tones (brap); clear entry errors with * * or wait 10 seconds between entries (§2.5).

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Remove keypad housing from the bottom edge (S&G logo side), replace both batteries, support battery holders. iButton Touch Key transfers audit trail and authorizes Service Mode users (§2.11); requires Lock Management System or Audit Manager software.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

73* set date (Bank Mode only); 74* add/delete User PIN Codes and set time delay; 77* PIN-position confirmation; 78* set time (Bank Mode only).

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Download uses Programmer PIN 00 plus cipher code from LMS; yellow LED on during ~20 s transfer; three beeps on success.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Dual Control — two independent valid User or Management codes required to open.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

all User Codes can send duress, including during programming; Factory default: duress disabled (§1.3).

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

User enters code to start delay; LED flashes and single beep every 10 s during delay; 10 rapid beeps when delay expires; during opening window beep+LED twice every 6 s; if not opened in window, lock resets.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Changes to an already-set delay/window only during the opening window; do not set delay until other programming is finished; Command 74* function 00 = delay minutes; function 01 = opening window.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

The bolt position indicator is a dry-contact switch rated 200 VDC, 0.5 A maximum: black is common, green closes to black when the bolt is retracted, and red closes to black when it is extended.

Sargent and Greenleaf Model 6128 A-Series Installation Instructions, 630-821, July 2010 · Sargent & Greenleaf, Inc., Nicholasville, Kentucky · 2010

A blue wire loop forms a secure loop, a closed circuit that outside switches can use to signal the lock. The bolt will not retract while that loop is broken.

Sargent and Greenleaf Model 6128 A-Series Installation Instructions, 630-821, July 2010 · Sargent & Greenleaf, Inc., Nicholasville, Kentucky · 2010

install test

Before installation, with fresh batteries in the keypad, run the lock's factory test entry: the bolt should retract, then extend 6 seconds later.

Sargent and Greenleaf Model 6128 A-Series Installation Instructions, 630-821, July 2010 · Sargent & Greenleaf, Inc., Nicholasville, Kentucky · 2010

lock options

A-Series kit order numbers: 6128-247 kit, auto relocking square bolt, 2-battery keypad, satin chrome; 6129-240 kit, push/pull square bolt, 2-battery keypad, satin chrome.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

specifications

A-Series (Models 6128/6129): bolt position indicator (BPI): yes; management reset code: not marked; marked lock body: Auto Relocking Square Bolt (motor lock); marked lock body: Push/Pull Square Bolt (motor lock).

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

A-Series (Models 6128 and 6129): tested and proven ATM security; streamlined, economical format; easy access and auditing It shares the three modes of operation and the 4/8/12/24-hour code window, time delay 1-99 minutes, penalty lockout and optional duress module described on the page.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Auto Relocking Square Bolt: motor retracts the bolt to open and spring extension closes it; withstands 225 pounds of bolt-end pressure; does not require direct attachment of the bolt to the safe boltwork. (Chart marks this lock body type.)

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Push Pull Square Bolt: motor retracts the bolt to open and motor extends it to close; designed for direct boltwork attachment; bolt has drilled and tapped holes; maximum load 5.6 pounds; Push/pull strength 2.4 pounds force.

Sargent and Greenleaf Product Catalog, March 2021 · Sargent and Greenleaf · 2021

Electronic Lock Features Chart (rev 6/23/2014), column 6128 A-SERIES: dual user, manager/employee modes; programmer code; 2 officer codes; 4 administrator codes; 10 user codes; total 16; duress module 6102-090; time delay 1-99 min; penalty lockout; BPI order 6128-230; motor drive.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

A-series ATM lock: up to sixteen users in Bank Mode (1 programmer, 2 officer, 4 administrator, 10 user codes).

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

Factory defaults as printed (§1.3): Bank Mode is on and is not time-restricted; Multi-User operation is on; Time Delay is zero (0) minutes; Duress is off; audit download is on; Set Date / Time is on.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Dual control and manager/employee modes are chosen with a special keypad command; snap-in touch key reader; penalty time; time delay 1-99 minutes.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

400-event audit trail (software kit 6103-120) with the time kept in the lock; duress via module 6102-090 or alarm interface module 6102-025; every model has a bolt position indicator.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

The 6128 is made for boltwork blocking applications.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

The product chart lists Multiple User Mode for the A-series, but this model description lists only dual control and manager/employee.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

Footnote *: total counts only codes that open the lock (not time delay override or programming/audit codes). **: with time delay override disabled an extra user code is available (max 9 user codes; 8 if override enabled), 3 available when duress is enabled.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

FLAG: chart marks Multiple User Mode; product page lists only dual control and manager/employee; March 2021 catalog dropped the Multiple User Mode row (neither confirms nor refutes); no value is given for Multiple User Mode.

Sargent and Greenleaf Product Catalog, July 2014 · Sargent and Greenleaf, Nicholasville, Kentucky · 2014

supplied parts

The keypad cable has four conductors and the keypad extension cable has five. A number plate, a serial number label and a keypad extension base come in the kit.

Sargent and Greenleaf Model 6128 A-Series Installation Instructions, 630-821, July 2010 · Sargent & Greenleaf, Inc., Nicholasville, Kentucky · 2010

notes

6124-6129 and Z03 respond to the * 8 # test with a long steady error tone; then 4 3 * separates the models (see the 6120/6123 identification entry for the beep table).

SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009

Not printed in the article: lockout after wrong entries, anti-manipulation, anti-autodialer, battery chemistry or external battery pack. (Drill points and opening methods are mentioned as differing by model but are not described.)

SAVTA Electronic Lock Guide, Part 2, Sargent & Greenleaf, May 2009 · 2009

Document 630-600 cover: Aseries Access Management System, Programming and Operations Guide, Models 6128 and 6129. Indoor use only; clean keypad with soft dry cloth (no solvents); never lubricate lock or keypad; support keypad when removed so it does not hang by the cable; each accepted keystroke beeps and lights the LED; all codes end with #.

Sargent and Greenleaf Models 6128 and 6129 Aseries Programming and Operations Guide, Document 630-600, revised 10/28/09 · 2009

Modifying the lock, including adding bolt attachments, is not recommended and voids the warranty.

Sargent and Greenleaf Model 6128 A-Series Installation Instructions, 630-821, July 2010 · Sargent & Greenleaf, Inc., Nicholasville, Kentucky · 2010

Restricted

Bypass

Member content. 1 fact on file. The values are not shown here.